Double Pipe Heat Exchanger Design 2.0

SPONSORED LINKS

    Specification

  • Version: 2.0
  • File size: 16 MB
  • File name: dhexdemo.exe
  • Last update:
  • Platform: WinXP,WinVista,Win7 x32,Win7 x64,Win98
  • Language: English
  • License: Demo
  • Expire: 30
  • Price:$75.00
  • Company: WeBBusterZ Engineering Software (View more)

Double Pipe Heat Exchanger Design 2.0 Download Publisher Review:



Double Pipe Heat Exchanger Design' 2.0 is Demo Math & Scientific Tools software design by WeBBusterZ Engineering Software. It runs on following operating system: WinXP,WinVista,Win7 x32,Win7 x64,Win98 and has as system requirements: Windows operating system, 20MB Free space. DHex is a software tool that is made to demonstrate the chemical design calculations of Double pipe (hairpin) Heat Exchangers.The software will do all the thermal calculations involved in the design and will generate a summary of all results..etc

Double Pipe Heat Exchanger Design 2.0 has been tested and received a complete evaluation by the Soft32Download experts and due to the great results it has been awarded with the "Clean & Safe" award, meaning that this product is 100% clean of adware/spyware/trojans/viruses and it is safe to install.


Whats new in version 2.0:
Enhanced interface, added physical properties database, fouling database and fixed few bugs

Publisher review:
-Software Features-
+Step by step calculation
+Support S.I & English (U.S) Units of measurement.
+Ability to import properties to Hot/Cold sides from Microsoft Excel.
+Save/Load results
+Export Results to Microsoft Excel
-Calculations-
+Calculate unknown Cold or Hot side temperatures.
+Perform thermal analysis for bare tube double pipe (hairpin) heat exchangers.
+Perform thermal analysis for finned tube double pipe (hairpin) heat exchangers.
+Choose from Counter Current or Co-Current Flow arrangement
+Choose from Series arrangement or Series-Parallel arrangement.
+The software will also tell you the location of Hot/Cold fluids within the heat exchanger (Inner Pipe or Outer Pipe).
+Select from different correlations to calculate Cold/Hot side heat transfer coefficient. Also the ability to adjust Nusselt number if you do have a different correlation.
+Calculate the Area, Flow area, Length, Log Mean Temperature Difference, Number of Hairpins, Unknown Flow rate.
+Calculate the scale resistance (dirt factor), Equivalent Diameter.
+Calculate Pipe/Annulus side Reynolds, Nusselt numbers & Prandtl Numbers.
+Duty, Clean and Design Overall heat transfer coefficient calculations
+Pipe/Annulus velocities and Mass velocity calculations
+Number of Transfer Units & Thermal Capacity ratio calculation.
+Clean and Fouled Fin Efficiency calculations for finned tube heat exchanger.
+Pressure drop calculations & Entrance and Exit losses.
-Included databases-
+Physical properties estimation of pure components for more than 1450 components; the database has the ability to estimate Thermal Conductivity, Density, Heat Capacity and Viscosity. The database also included & come as a standalone interface but easily integrated with the software.
+Estimate mixture properties. (ALL ESTIMATION METHODS CURRENTLY SUPPORT LIQUIDS ONLY)
+User database functions to allow user to add/delete components and load to hot/cold side (Empty database!).
+Fouling factors
Requirements:
Windows operating system, 20MB Free space

Operating system:
WinXP,WinVista,Win7 x32,Win7 x64,Win98

Limitations:
30 Days Demo

Release notes:
New Release

Related downloads:

Latest news

IE 10 for Windows 8, comes with Adobe Flash support

IE 10 for Windows 8, comes with Adobe Flash support

After criticism received at Metro version of Internet Explorer 10 , initially offered no support for Adobe Flash technology, Microsoft has taken measures to correct this problem by working directly with Adobe to integrate the necessary components into the

Posted on: 25 May 2012 10:36 by A. Brown

Windows 8: boot to fast to furious

Windows 8: boot to fast to furious

Last year began to circulate on the Internet videos where Windows 8 systems boot in 7 seconds. Unfortunately, from this performance derives some problems.

Posted on: 25 May 2012 07:28 by A. Brown

Apple prepares iPhone 5 and iOS 6

Apple prepares iPhone 5 and iOS 6

New information coming from some sources close to Apple confirming that the Cupertino giant is testing two different models of iPhone, called internal iPhone5, 1 and iPhone 5.2. Apparently, both devices have a screen of 3.95 inches and a resolution of 113

Posted on: 24 May 2012 08:36 by A. Brown

Windows 8 estimates: 500 million users in 2013

Windows 8 estimates: 500 million users in 2013

Microsoft expects to launch a new wave of optimism with Windows 8. In a recent statement, Steve Ballmer, chief executive at Microsoft, estimates that Windows 8 will reach a total of about 500 million users by the end of 2013.

Posted on: 24 May 2012 08:25 by A. Brown

SPREAD THE WORD

User Rating

Double Pipe Heat Exchanger Design
Rating: 3.0 out of 5
Based on 1 ratings. 1 user reviews.

  • Currently 3.00 out of 5
  • 1
  • 2
  • 3
  • 4
  • 5

Screenshot:

Double Pipe Heat Exchanger Design 2.0 screenshot. Click to enlarge!
Screenshots(1)

Awards

Double Pipe Heat Exchanger Design 2.0 Clean & Safe award